DATE: __________________________
PROJECT: __________________________________________
MECHANICAL CONTRACTOR: _____________________________
Model 155MAX
ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two
airstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS -
Each air stream has one centrifugal
blower driven by a common PSC motor. 5 speed fan operation.
120 VAC, 1.0 Amps.
FILTERS - Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
- Four threaded inserts at corners of case
designed to accept four reinforced polyester straps that are supplied
with the unit.
DEFROST - Recirculating damper defrost system.
DEHUMIDISTAT - Adjustable Internal Dehumidistat.
CASE - Twenty gauge prepainted galvanized steel (G60) for superior
corrosion resistance. Insulated to prevent exterior condensation.
Drain connections 2 -
1/2
" (12 mm) OD.
CONTROLS - ControlAir 15
WEIGHT 71 lbs. (32.5 kg) SHIPPING WEIGHT 73 lbs. (33.5 kg)
PERFORMANCE
HVI CERTIFIED
Net supply airflow in cfm (L/s) against external static pressure
E.S.P cfm L/s
@ 0.1” (25 Pa) 169 (80)
@ 0.2” (50 Pa) 161 (76)
@ 0.3” (75 Pa) 150 (71)
@ 0.4” (100 Pa) 130 (61)
@ 0.5” (125 Pa) 56 (26)
Maximum Temperature Recovery 83%
Sensible Effectiveness
@ 64 cfm (30 L/s)
(CSA C439M)
76%
Sensible Efficiency
@ 64 cfm (30 L/s) 32°F (0
O
C) 70%
Sensible Efficiency
@ 64 cfm (30 L/s) -13°F (-25
O
C)
70%
VAC @ 60HZ 120
WATTS / Low speed 49
WATTS / High speed 120
Amp rating 1.0
BALANCING DAMPER
32 5/8"
(828)
STALE AIR
FROM INSIDE
FRESH AIR
FROM OUTSIDE
STALE AIR
TO OUTSIDE
FRESH AIR
TO INSIDE
14 3/4"
(375)
19"
(483)
*All Duct Connections 6" (150mm)
CONDENSATE DRAINS
FILTERS
BLOWERS
*NOTE: Front clearance 
of 25 inches (635 mm) 
is recommended 
for servicing unit.
RECIRCULATING
DEFROST
DAMPER
MOTOR
CORE
DIMENSIONS 155MAX
inches (mm)
OPTIONS
99-104 Digital Electronic Timer - 20/40/60 min.
99-105 Programmable Ventilation Control
(PVC)
includes Programmable Time Clock, Dehumidistat
and Air Sentry™
99-109 Air Sentry™ Air Quality Monitor designed to
accept remotely mounted Control Pad
99-250 Ventilation Dehumidistat - Dehumidistat designed
to accept remotely mounted Control Pad.
99-163 Duct Heater w/ Electronic SCR Thermostat, 1 Kw,
6” (150 mm)
99-164 Duct Heater w/ Electronic SCR Thermostat, 2 Kw,
6” (150 mm)
99-186 Weatherhoods, Two - 6” (150 mm)
c/w 1/4” (6 mm) mesh screen
All units conform to CSA and UL standards.
WARRANTY
Units carry a LIFETIME warranty on the heat recovery core and
a 5 year replacement parts warranty.
TI-92-NE
0202
511 McCormick Blvd.
London, Ontario
N5W 4C8
Ph: (519) 457-1904
Fx: (519) 457-1676
Website: www.lifebreath.com